Operator 1
Schematic envelope. Rates are not a calibrated time scale.
Instrument settings, voice editing and musical data.
Use desktop Chrome or Edge over HTTPS. Connect both MIDI directions and allow System Exclusive access. Match System channel to the setting on your FM-01.
Read the connected instrument to begin
Values are sent live. Reset returns a parameter to the value last read from the device. Shared channels receive the same MIDI notes and controllers. Pan is left / both / right.
Edits are sent to this instrument’s working voice. To keep a reusable sound, store it in a user bank below. Total Level 0 is loudest; 127 is quietest.
The YM2164 LFO is shared. Enable LFO response and select the PMD controller source in Instrument settings. Loading a sound with “Load LFO” enabled can change the global LFO.
Schematic envelope. Rates are not a calibrated time scale.
Schematic envelope. Rates are not a calibrated time scale.
Schematic envelope. Rates are not a calibrated time scale.
Schematic envelope. Rates are not a calibrated time scale.
Stored with the voice. These are imported when a sound is selected with Combine enabled.
For experienced editors. Values are decimal. Unchanged bits and reserved bytes are preserved by the normal controls above. Raw edits replace the entire byte.
Replaces one stored user sound. Enable user-memory writing in the shared protection panel below. The saved voice is read back for verification.
Single assigns eight voices to Instrument 1. Dual layers two four-voice sounds; Split divides the keyboard. Recalling replaces the working arrangement.
Saves part settings and sound references, not copies of the voices themselves. Enable user-memory writing below.
Tuning and protection are not part of a standard configuration dump. The tuning box is a send value, not a readback of the current setting. The LFO has shared global resources.
Read configuration names to show the names of all sixteen saved arrangements.
Read banks, working voices and configurations as standard musical SysEx files. A complete musical backup needs all five user banks and the configuration library.
No dump read yet.
One voice, bank or configuration dump per file. Files are checked before sending. Working voices load into the selected instrument; bank reception only permits user destinations.
No file selected.
Target: choose a file first
Read a bank to browse its forty-eight stored voices.
All 240 original factory voices are included in this page. Load one into the selected working instrument to audition or edit. This does not overwrite a stored user sound.
Get the latest firmware from this website. Your user banks and saved settings are kept.
0%
Keep this tab open and the device powered until the result is confirmed. An interrupted update can be restarted from the beginning.
Use this guide while working with the FM-01 controller. Choose a topic below. Help is available before connecting a device.
The System channel addresses SysEx. Each instrument’s MIDI channel routes notes and performance controls. They are separate settings. The web controller does not generate audio: listen to the FM-01’s physical audio outputs.
Click one of the eight instrument cards to choose the part you are editing. The page reads its current settings and working voice. The selected instrument is used by the editor, keyboard and performance controls.
Assigned voices is the part’s available polyphony. All eight parts share a total of eight voices; a part assigned zero is silent. To give a second part four voices, first reduce Instrument 1 from eight to four, then select Instrument 2 and assign four. If its maximum is zero, other parts already use all available voices.
Lowest note and Highest note are MIDI note limits. Octave transposes the selected part. Poly mode still obeys Assigned voices; it does not increase the total polyphony. Octave labels can differ between devices: compare MIDI note numbers when matching ranges.
Above the keyboard in Play & listen, choose Bank and Voice, then click Select sound. This replaces the selected part’s working sound. Read bank names reads the stored names of that bank without selecting a new sound.
Banks 1 and 2 are User 1 and User 2; banks 3–7 are ROM 1–ROM 5; banks 8–10 are User 3–User 5. Each contains 48 voices. Factory banks are read-only in normal operation.
Library → Browse a device bank reads all 48 stored voices. Choose one and click Select on instrument to use that bank and voice. The separate Factory voice library loads a built-in factory sound into the working buffer for auditioning or editing; it does not overwrite a user-bank sound.
When Combine is enabled, selecting a stored sound can also load its portamento time, Mono/Poly mode, bend range and modulation source. Use Read current instrument after making changes from the hardware panel or another MIDI application.
Voice editor works on the selected instrument’s current sound. Changes are sent live. The voice has four operators, an algorithm, feedback, LFO settings and performance settings stored with the voice.
Reset beside a parameter returns it to its last read value. Restore last read voice restores the whole working voice to that snapshot. Read working voice replaces the editor’s snapshot with the current device data. Export voice .syx saves the current editor sound as a musical SysEx file.
Raw voice bytes are for advanced editing. A raw-byte change replaces the whole byte. The ordinary controls preserve unrelated bits and reserved data.
In Instrument settings, enable LFO response and choose the Modulation source. Use Modulation wheel for CC1, Breath for CC2, Foot for CC4 or Channel pressure for aftertouch. Moving another controller will not substitute for the selected source.
The voice also needs suitable pitch or amplitude sensitivity and depth. Try a known sound that responds to modulation. The YM2164 has shared global LFO resources: changing LFO speed or waveform can affect more than one part. Load LFO with voice determines whether a selected sound imports its LFO settings.
Working edits and bank storage are separate. Store writes one reusable bank sound and does not change the current bank/voice selection. Select the destination explicitly to hear the saved copy. A configuration pointing to an overwritten sound will use its replacement.
By default, Re-enable Write Protect after the operation is checked. The controller enables protection again after a storage operation and clears the write permission checkbox.
A configuration stores the arrangement: voice allocation, MIDI channels, note ranges, sound references and performance settings. It does not contain independent copies of every sound.
To save your own arrangement, apply its working name, choose User 1–16, enable user-memory writing and click Store & verify configuration. To restore it later, select that User slot and click Recall configuration. Read configuration names in Library reads the names of the sixteen stored arrangements.
Working settings are remembered by the device, but a named User configuration is the way to keep several selectable arrangements. Master tuning and Write Protect are not fields of a standard configuration dump. The tuning box sends the entered value; it is not readback of the current tuning.
In Library, choose the data, click Read from FM-01, wait for verified reception, then click Download last dump .syx. For a complete stored musical backup, save all five user banks and All user configurations · Conf.ME. Save the current configuration separately if required.
Config means the current working arrangement. Conf.ME means all sixteen stored User configurations. Receiving one does not perform the other operation.
To import, open one musical .syx dump or hexadecimal .txt file. Check the target and click Send & verify. Working voices load into the selected instrument. For a bank, choose a writable user bank. Stored bank and configuration writes require user-memory permission; complete bank/library replacements also ask for confirmation. Do not remove power during storage.
The keyboard sends notes on the selected part’s MIDI channel. Other parts on that channel will sound too. Set Velocity from 1–127. Enable the computer-keys checkbox to play the indicated keys; typing in text or number fields does not trigger notes.
Sustain (CC64) holds released notes. Sostenuto (CC66) captures notes already held when engaged. Portamento uses its switch (CC65) and time (CC5). Performance sliders send values; they do not read current controller positions from the device.
Choose a bank and voice directly above the keys, in any musical tab. Use −/+ Semitone for a one-semitone shift or −/+ Octave for twelve semitones; Reset returns to zero. The range is −48 to +48 semitones. This affects only the page’s screen and computer keyboards, not the instrument’s Octave or tuning settings. Changing the shift releases held notes, Sustain and Sostenuto. Labels and the displayed note range follow the sounding pitches.
All Notes Off sends CC123 on the selected MIDI channel. It behaves like releasing keys: Sustain can keep notes sounding. For immediate silence use the top All Sound Off button. In this controller it releases Sustain and Sostenuto and sends stopping commands on all sixteen channels.
Reset controllers sends CC121. It is separate from clearing the MIDI log and does not erase sound banks.
The normal application-only update preserves user banks and settings. Factory-install packages are rejected by this page. If stopped or interrupted, remain in update mode and restart the same update from its beginning. Reaching the end of transmission alone is not success; the page waits for device verification.
MIDI activity shows recent sent and received messages. Save MIDI log downloads the history as JSON. Clear log empties this history; new activity is recorded normally. Clearing the log leaves the instrument’s settings, sounding notes and any ongoing operation unchanged.
Working edits do not write a user-bank slot. Store and bank/configuration imports can replace saved data. Choose the destination carefully.
Protection state is not in a standard configuration dump. Check the device display.
Plays on the selected instrument’s MIDI channel. Parts sharing that channel will sound together.
Factory names are built in. Read a user bank to display its stored voice names. Selecting a sound replaces this instrument’s working voice.
C3–C5 · MIDI notes 48–72
Performance sliders send MIDI values; they do not read the current controller positions from the device. Keyboard octave labels use MIDI note 60 = C4. Transpose affects only this page’s on-screen and computer keyboards. Changing transpose releases held notes and hold pedals.
No messages.